Chinese product page · English
Standard RO equipment · QZ-RO500
A compact RO system for your water-use requirements. We review the configuration against your source water, daily demand and required water quality.
Assembled by Qingze in Dongguan, China. View our assembly work. Enquiries welcome in English or Chinese.

Know what the standard quotation covers
Production and dispatch: Made to order. We dispatch 7 days after the order is placed. Transit time is additional.
Included
- Pretreatment equipment
- RO main unit
Not included
- Raw-water feed pump
- Water storage tanks
- Water distribution pump
Confirm pretreatment details, accessories, freight, installation responsibilities and any additional equipment in the agreed supply list. If your feedwater is from a well, tank or another source, request a configuration review before ordering.
Check the equipment against your site
- Model
- QZ-RO500
- Treatment
- Pretreatment followed by reverse osmosis
- Power supply options
- 220 V, single phase, 50 Hz or 380 V, three phase, 50 Hz. Select the configuration before ordering.
- High-pressure pump model
- CDL2-11
- RO membrane model
- BW30-4040L
- Standard inlet arrangement
- Direct connection to a mains-water line, subject to confirmation of feedwater quality, pressure and site connections.
Nominal output is a selection reference. Actual permeate output depends on source water and operating conditions. Allow additional space for connections, servicing and equipment access.
The dimensions shown are equipment dimensions, not packed shipping dimensions. Confirm the number of packages, each package’s external dimensions and gross weight before arranging transport.
Custom project experience
Qingze water-treatment project in Senegal
Qingze Systems supplied a two-pass RO system for the expansion of a bottled-water and beverage business in Senegal. This was a custom system with second-pass permeate output of 6 m³/h, separate from the QZ-RO500 standard model on this page.

How this custom project handled source-water constraints
The first RO pass produced 9 m³/h and fed the second pass, which produced 6 m³/h. These are stages in series, so the two outputs are not added together. The project’s deep-well source water had conductivity of 1,300 µS/cm and hardness of 178 mg/L.
When the customer reported insufficient well-water supply, a separate RO concentrate-recovery unit was added. Recovered permeate returned to the raw-water tank, mixed with groundwater and went through the main treatment system again. It was not supplied directly to beverage production.
For your project, equipment selection should consider source-water quality, daily demand, supply limitations and site connections. Recovery conditions must be assessed for the specific water and system.
View the full Senegal project in English →
Single-pass RO for aluminium processing
Our Senegal aluminium-factory project used pretreatment and a 2 m³/h single-pass RO system, with installation carried out by the customer and guidance from Qingze. This is a separate custom project, not the QZ-RO500 model or its supply scope.
View the aluminium-processing RO project and actual equipment photos →
Send your conditions. Get a configuration and quotation.
Tell us your water source, intended use and approximate daily demand. A water report and site photos can follow.
WhatsApp: +86 159 8676 5882
Email: sales@qingzesystems.com
You can also use our Chinese-language enquiry form. Please avoid sending unnecessary personal information. See our privacy statement in English, or read the English summary below.
Compare RO500 and RO1000 configurations
Compare 500 L/h and 1000 L/h RO systems
Compare the nominal output, equipment footprint and supplied equipment alongside your daily consumption and available operating hours.
QZ-RO500 · 500 L/h
- Equipment dimensions: 900 × 600 × 1600 mm
- Specified equipment power: 1.1 kW
- Standard supply: pretreatment and RO main unit
- Raw-water pump, storage tanks and distribution pump are not included
QZ-RO1000 · 1000 L/h
- Equipment dimensions: 1000 × 600 × 1600 mm
- Specified equipment power: 1.5 kW
- Standard supply: raw-water pump, pretreatment and RO main unit
- Storage tanks and distribution pump are not included
Nominal capacity alone does not determine suitability. Share source-water quality, peak demand, operating hours and required final-water quality so the complete configuration can be reviewed.
For a larger capacity or different treatment process, review standard and custom industrial RO options.
Selection guides, water-analysis checklist and PDF
Save the specifications and quotation checklist
Share the RO500 / RO1000 model comparison and supply scope with your team before discussing the final configuration.
English PDF · 2 pages · approximately 10 KB. Includes equipment specifications, supply scope and the information to prepare for a quotation.
Three questions before selecting 500 L/h
How much water do you need?
Share daily consumption, operating hours and peak demand. For planning only, 500 L/h over eight operating hours gives 4,000 litres before allowing for real operating conditions and downtime.
What water quality does production require?
State the application and required final-water specification. If available, send a recent source-water analysis. Equipment suitability must be assessed for your process.
Is the site ready?
- Check incoming voltage, phase and frequency.
- Check the incoming water supply and pressure.
- Plan permeate storage, distribution and concentrate drainage.
- Allow room to move the equipment into position and service it.
No fixed recovery rate, final-water quality or operating cost is assumed without reviewing your conditions.
What water-analysis report should you send for an RO quotation?
Water-report details and a project brief
Share the full laboratory report, sampling date, sampling point and units. Include the source-water temperature range where known. Useful measurements include pH, conductivity or TDS, hardness, alkalinity, iron, manganese, silica, turbidity and free chlorine. Keep the report’s units intact; hardness may be reported as CaCO3. A handheld TDS reading alone does not describe all constituents needed for a design review.
Keep source water and final-water requirements separate
Tell us whether the sample is mains water, well water, tank water or water after existing treatment. Describe where the treated water will be used and provide your production-water specification separately.
Prepare a short project brief
- Country and production application
- Water source and available analysis report
- Required water quality at the point of use
- Daily consumption, peak demand and operating hours
- Available voltage, phase, frequency and inlet pressure
- Existing storage, distribution equipment and installation space
If a report is not yet available, start with the information you have. We can review it and discuss what else is needed before confirming the configuration. Send report files by email or WhatsApp and include a short summary in the online enquiry.
Use the full water-report checklist and copy a project brief →
Send your RO500 requirements →
Technical reference: DuPont FilmTec technical manual — water analysis for RO/NF. The quotation configuration is assessed for your own water and site.
Check demand before selecting capacity
Review daily volume, peak demand, production hours and usable storage together before choosing a nominal flow.
Compare 250, 500 and 1000 L/h RO systems →
Compare nominal output against daily use and operating hours, then copy a brief to discuss your requirements.
Privacy and your enquiry
This website is operated by Dongguan Qingze Environmental Protection Technology Co., Ltd. under the Qingze Systems brand. We use the information you choose to send to answer your questions, assess equipment requirements, prepare quotations and follow up on your enquiry. Please send only information relevant to your enquiry.
Website enquiries are stored in website records and sent to our business email. Records may include relevant page paths, referring sites and campaign source labels. Enquiry messages and contact details are not sent as Google Analytics event content.
Optional Google Analytics 4 statistics load only after you allow them. Rejecting statistics does not prevent browsing or submitting an enquiry. Use Analytics settings to choose Allow or Reject, or to change your choice. Withdrawing consent stops subsequent optional statistics; it does not automatically delete data already processed by Google. Server security logs are handled separately.
Hosting, email and analytics providers process information as needed to provide their services; infrastructure may be outside your country. Interactions with WhatsApp, WeChat and other external platforms are also subject to those platforms’ own privacy policies.
Enquiry records do not currently have a uniform automatic deletion period. Retention depends on enquiry handling, quotations, contracts, after-sales service and applicable record-keeping requirements. To ask about access, correction or deletion, email sales@qingzesystems.com. We may need to verify your connection to the relevant records.
Read our full privacy statement for more detail. Contact us if you need clarification before sharing information.